Selection Guide - DIN RAIL Series |
|
|
|
|
Model
|
Wattage
|
Input (Remark1)
|
Single Phase Single Output Current (A)
|
Features (Remark2)
|
Certificates (Remark3)
|
Dimensions (LxWxH) (mm)
|
Warranty (Year)
|
|
5V
|
12V
|
15V
|
24V
|
48V
|
|
|
10
|
F
|
2
|
0.84
|
0.67
|
0.42
|
|
A B P
|
L T B E
|
22.5 x 90 x 100
|
3
|
|
|
15
|
F
|
2.4
|
1.25
|
1
|
0.63
|
|
A B P
|
UC T B E
|
25 x 93 x 56
|
3
|
|
|
20
|
F
|
3
|
1.67
|
1.34
|
1
|
|
A B P
|
L T B E
|
22.5 x 90 x 100
|
3
|
|
|
30
|
F
|
3
|
2
|
2
|
1.5
|
|
A B P
|
UC T B E
|
78 x 93 x 56
|
3
|
|
|
40
|
F
|
6
|
3.33
|
|
1.7
|
0.83
|
A B P
|
L T B E
|
40 x 90 x 100
|
3
|
|
|
45
|
F
|
5
|
3.5
|
2.8
|
2
|
|
A B C P
|
L T B E
|
78 x 93 x 67
|
3
|
|
|
60
|
F
|
6.5
|
4.5
|
4
|
2.5
|
|
A B P
|
UC T B E
|
78 x 93 x 56
|
3
|
|
|
60
|
F
|
10
|
5
|
|
2.5
|
1.25
|
A B P
|
L T B E
|
40 x 90 x 100
|
3
|
|
|
75
|
F
|
|
6.3
|
|
3.2
|
1.6
|
A B C P
|
L T B E
|
55.5 x 125.2 x 100
|
3
|
|
|
100
|
F
|
|
7.5
|
6.5
|
4.2
|
|
A B C P
|
L T B E
|
100 x 93 x 56
|
3
|
|
|
100
|
F
|
|
8
|
|
4
|
2
|
A B P
|
UC T B E
|
55 x 90 x 100
|
3
|
|
|
120
|
S
|
|
10
|
|
5
|
2.5
|
A B C P
|
UC L T B E
|
65.5 x 125.2 x 100
|
3
|
|
|
120
|
F
|
|
10
|
|
5
|
2.5
|
A B C F J P
|
L T B E
|
40 x 125.2 x 113.5
|
3
|
|
|
240
|
F
|
|
|
|
10
|
5
|
A B C J P
|
UC L T B E
|
125.5 x 125.2 x 100
|
3
|
|
|
240
|
F
|
|
|
|
10
|
5
|
A B C F J P
|
L T B E
|
63 x 125.2 x 114
|
3
|
|
|
480
|
F
|
|
|
|
20
|
10
|
A B C F J P
|
L T B E
|
85.5 x 125.2 x 128.5
|
3
|
|
|
480
|
230
|
|
|
|
20
|
10
|
A B C K P
|
UC L T B E
|
227 x 125.2 x 100
|
3
|
|
|
480
|
S
|
|
|
|
20
|
10
|
A B C K P
|
UC L T B E
|
227 x 125.2 x 100
|
3
|
|
Model
|
Wattage
|
Input (Remark1)
|
Three Phase Single Output Current (A)
|
Features (Remark2)
|
Certificates (Remark3)
|
Dimensions (LxWxH) (mm)
|
Warranty (Year)
|
|
24V
|
48V
|
|
|
120
|
H
|
5
|
5
|
A B C P
|
UC L T B E
|
65.5 x 125.2 x 100
|
3
|
|
|
240
|
H, 3ø
|
10
|
5
|
A B C P
|
UC L T B E
|
125.5 x 125.2 x 100
|
3
|
|
|
480
|
H, 3ø
|
20
|
10
|
A B C P
|
UC L T B E
|
227 x 125.2 x 100
|
3
|
|
|
960
|
H, 3ø
|
40
|
20
|
A B C P
|
UC L T B E
|
276 x 125.2 x 100
|
3
|
Remark 1:
F - Universal AC input/Full range S - 115/230VAC Selectable A - 115/230VAC Auto sensing 230 - 230VAC only H - 340~550VAC 3ø - 3 phases
Remark 2:
| A - Short circuit, overload protection |
I - Parallel function |
Q - Output voltage adjustable externally |
| B - Over voltage protection |
J - Active PFC function |
R - No min. load for CH2,3,4, adjustable from -5~+10% |
| C - Over temperature protection |
K - Passive PFC function |
S - No min. load for CH2,3 and adjustable by ±5% |
| D - Fan ON/OFF control |
L - 5G Anti-vibration |
T - ON/OFF Switch |
| E - Fan speed control |
M - Fan error alert |
U - Full output 3~48VDC safety approved |
| F- PF/PG Signal output |
N - 12(5)V/0.1A Auxiliary output |
V - Low battery voltage protection |
| G - TTL Signal remote control |
O - Built-in DC fan |
W - Battery polarity protection |
| H - Remote sense |
P - Free air cooling |
- Medical standard |
Remark 3: Safety Certificate
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
UC
|
U
|
L
|
CU
|
T
|
G
|
B
|
S
|
TM
|
E
|
D
|
F
|
CC
|
|