Selection Guide - Medical PCB Type PDF Print E-mail
Model
Wattage
Input
(Remark1)
Single Output Current (A)
Features
(Remark2)
Certificates
(Remark3)
Dimensions
(LxWxH) (mm)
Warranty
(Year)
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
30
F
 
5.0
 
2.5
 
2.0
1.2
1.1
0.6
A B C
UC T B E
101.6 x 65.8 x 23.5
3
45
F
8.0
8.0
5.4
3.7
3.3
3.0
1.9
1.7
1.0
A B
UC T B E
127 x 76 x 28
3
60
F
11
11
 
5.5
 
4.4
2.75
 
1.375
A B
UC T B E
101.6 x 50.8 x 29
3
65
F
12
12
8.0
5.2
4.7
4.2
2.7
2.4
1.35
A B
UC T B E
127 x 76 x 42
3
75
F
20
20
 
8.3
 
6.7
4.2
2.8
2.1
A B
UC T B E
127 x 76.2 x 30.5
3
120
F
24
22
 
10
 
8.0
5.0
 
2.5
A B
UC T B E
177.8 x 108 x 35.5
3
160
F
30
 
 
12.9
 
10.3
6.5
 
3.25
A B C
UC T B E
127 x 76.2 x 33
3
200
F
40
40
 
16.7
 
13.4
8.4
 
4.2
A B C
UC T B E
177.8x107.2x35.5
3

Model
Wattage
Input
(Remark1)
Multi Output Current (A)
Features
(Remark2)
Certificates
(Remark3)
Dimensions
(LxWxH) (mm)
Warranty
(Year)
3.3V
5V
12V
15V
24V
-5V
-12V
-15V
45
F
 
5.0
2.5
 
 
 
 
 
A B
UC T B E
127 x 76 x 28
3
45
F
 
5.0
 
 
1.8
 
 
 
A B medical
UC T B E
127 x 76 x 28
3
60
F
 
5.5
2.2
 
 
 
 
 
A B
UC T B E
101.6 x 50.8 x 29
3
60
F
 
3.85
 
 
1.65
 
 
 
A B
UC T B E
101.6 x 50.8 x 29
3
65
F
 
7.2
3.2
 
 
 
 
 
A B
UC T B E
127 x 76 x 42
3
65
F
 
6.0
 
 
2.6
 
 
 
A B
UC T B E
127 x 76 x 42
3
75
F
 
9.5
4.0
 
 
 
 
 
A B
UC T B E
127 x 76.2 x 30.5
3
75
F
 
6.8
 
 
2.7
 
 
 
A B
UC T B E
127 x 76.2 x 30.5
3
120
F
 
12
6
 
 
 
 
 
A B
UC T B E
177.8 x 108 x 35.5
3
120
F
 
12
 
 
3.2
 
 
 
A B
UC T B E
177.8 x 108 x 35.5
3
200
F
 
24
9.6
 
 
 
 
 
A B
UC T B E
177.8 x 108 x 35.5
3
200
F
 
24
 
 
4.8
 
 
 
A B
UC T B E
177.8 x 108 x 35.5
3
45
F
 
5.0
2.5
 
 
0.5
 
 
A B
UC T B E
127 x 76 x 28
3
45
F
 
5.0
2.5
 
 
 
0.5
 
A B
UC T B E
127 x 76 x 28
3
45
F
 
5.0
 
2.3
 
 
 
0.5
A B
UC T B E
127 x 76 x 28
3
60
F
5.5
3.3
0.77
 
 
 
 
 
A B
UC T B E
101.6 x 50.8 x 29
3
60
F
 
4.4
2.2
 
 
0.55
 
 
A B
UC T B E
101.6 x 50.8 x 29
3
60
F
 
4.4
2.2
 
 
 
0.55
 
A B
UC T B E
101.6 x 50.8 x 29
3
60
F
 
4.4
 
1.65
 
 
 
0.55
A B
UC T B E
101.6 x 50.8 x 29
3
60
F
 
3.85
0.55
 
1.1
 
 
 
A B
UC T B E
101.6 x 50.8 x 29
3
65
F
 
7.0
3.2
 
 
0.7
 
 
A B
UC T B E
127 x 76 x 42
3
65
F
 
7.0
3.2
 
 
 
0.7
 
A B
UC T B E
127 x 76 x 42
3
65
F
 
7.0
 
2.6
 
 
 
0.7
A B
UC T B E
127 x 76 x 42
3
75
F
7.0
8.0
1.5
 
 
 
 
 
A B
UC T B E
127 x 76.2 x 30.5
3
75
F
 
8.0
4.0
 
 
1.0
 
 
A B
UC T B E
127 x 76.2 x 30.5
3
75
F
 
8.0
4.0
 
 
 
1.0
 
A B
UC T B E
127 x 76.2 x 30.5
3
75
F
 
8.0
 
3.0
 
 
 
1.0
A B
UC T B E
127 x 76.2 x 30.5
3
75
F
 
7.0
1.0
 
2.0
 
 
 
A B
UC T B E
127 x 76.2 x 30.5
3
120
F
 
12
5.8
 
 
1.0
 
 
A B
UC T B E
177.8 x 108 x 35.5
3
120
F
 
12
5.3
 
 
 
1.0
 
A B
UC T B E
177.8 x 108 x 35.5
3
120
F
 
11
 
4.4
 
 
 
1.0
A B
UC T B E
177.8 x 108 x 35.5
3
120
F
 
12
1.0
 
2.6
 
 
 
A B
UC T B E
177.8 x 108 x 35.5
3
200
F
 
24
9.0
 
 
2.4
 
 
A B C
UC T B E
177.8 x 108 x 35.5
3
200
F
 
24
7.2
 
 
 
2.4
 
A B C
UC T B E
177.8 x 108 x 35.5
3
200
F
 
24
 
5.6
 
 
 
2.4
A B C
UC T B E
177.8 x 108 x 35.5
3
200
F
 
24
2.4
 
3.6
 
 
 
A B C
UC T B E
177.8 x 108 x 35.5
3
120
F
 
11
5.0
 
 
1.0
1.0
 
A B
UC T B E
177.8 x 108 x 35.5
3
120
F
 
11
 
3.8
 
1.0
 
1.0
A B
UC T B E
177.8 x 108 x 35.5
3
120
F
 
11
1.1
 
2.3
 
1.0
 
A B
UC T B E
177.8 x 108 x 35.5
3
120
F
 
11
3.3
1.0
1.0
 
 
 
A B
UC T B E
177.8 x 108 x 35.5
3
200
F
 
18
8.4
 
 
2.4
2.4
 
A B C
UC T B E
177.8 x 108 x 35.5
3
200
F
 
18
 
6.0
 
2.4
 
2.4
A B C
UC T B E
177.8 x 108 x 35.5
3
200
F
 
18
2.4
 
3.6
 
2.4
 
A B C
UC T B E
177.8 x 108 x 35.5
3
200
F
 
18
 
2.4
3.3
 
2.4
 
A B C
UC T B E
177.8 x 108 x 35.5
3


Remark 1:
F - Universal AC input/Full range
S - 115/230VAC Selectable
A - 115/230VAC Auto sensing
230 - 230VAC only
H - 340~550VAC
- 3 phases

Remark 2:

A - Short circuit, overload protection I - Parallel function Q - Output voltage adjustable externally
B - Over voltage protection J - Active PFC R - No min. load for CH2,3,4, adjustable from -5~+10%
C - Over temperature protection K - Passive PFC S - No min. load for CH2,3 and adjustable by ±5%
D - Fan ON/OFF control L - 5G Anti-vibration T - ON/OFF Switch
E - Fan speed control M - Fan error alert U - Full output 3~48VDC safety approved
F- PF/PG Signal output N - 12V/0.1A Auxiliary output V - Low battery voltage protection
G - TTL Signal remote control O - Built-in DC fan W - Battery polarity protection
H - Remote sense P - Free air cooling - Medical standard

Remark 3: Safety Certificate